Visceral Manifold Study for the Repair of Thoracoabdominal Aortic Aneurysms
Valiant Thoracoabdominal Stent Graft System
Anévrisme aortique thoraco-abdominal+4
+ Anévrisme
+ Maladies aortiques
Étude thérapeutique
Résumé
Date de début de l'étude : 6 octobre 2020
Date à laquelle le premier participant a commencé l'étude.The primary objective is to assess the use of the thoracic bifurcation and the visceral manifold stent graft system to repair thoracoabdominal aortic aneurysms in patients with appropriate anatomy. The primary intent of the study is to assess safety (i.e. freedom from major adverse events (MAE) at 30 days) and preliminary effectiveness (i.e., treatment success and technical success) of the device (i.e., the proportion of treatment group subjects that achieve and maintain treatment success at one year). Additionally, the study will assess technical success and treatment success at each follow-up interval.
Protocole
Cette section fournit des détails sur le plan de l'étude, y compris la manière dont l'étude est conçue et ce qu'elle évalue.15 participants à inclure
Nombre total de participants que l'essai clinique vise à recruter.Traitement
Éligibilité
Les chercheurs recherchent des patients correspondant à une certaine description appelée critères d'éligibilité : état de santé général ou traitements antérieurs du patient.Tout sexe
Le sexe biologique des participants éligibles à s'inscrire.À partir de 18 ans
Tranche d'âge des participants éligibles à participer.Volontaires sains non autorisés
Indique si les individus en bonne santé et ne présentant pas la condition étudiée peuvent participer.Conditions
Pathologie
Critères
Inclusion Criteria: Primary Arm Inclusion Criteria: A patient may be entered into the study if the patient has at least one of the following: * An aneurysm with a maximum diameter of \> 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements * Aneurysm with a history of growth \> 0.5 cm in 6 months * Saccular aneurysm deemed at significant risk for rupture * Symptomatic aneurysm greater than or equal to 4.5 cm Other inclusion criteria * Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit * Proximal landing zone for the thoracic bifurcation stent graft that has: * ≥ 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA) and a diameter in the range of 26-42 mm * Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold * Iliac artery or aortic distal fixation site, including both native tissue and previously placed graft, greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm * Age: ≥ 18 years old * Life expectancy: \> 1 year Exclusion Criteria: Primary Arm Exclusion criteria * Patient is a good candidate for and elects for open surgical repair * Can be treated in accordance with the instructions for use with a legally marketed endovascular prosthesis * Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site * Unwilling to comply with the follow-up schedule * Inability or refusal to give informed consent by patient or legal representative * Urgent or emergent presentation * Patient is pregnant or breastfeeding * Patient has a contained rupture * Patient has a ruptured aneurysm * Patient has a dissection in the portion of the aorta intended to be treated * Obstructive stenting of any or all of the visceral vessels * Poor performance status including two major system failures (including but not limited to cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular) Medical exclusion criteria * Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel: Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE), platinum, gold, polyethylene, or stainless steel. * Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed * Uncorrectable coagulopathy * Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment * Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned \< 30 days of the endovascular repair * Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina) * Systemic or local infection that may increase the risk of endovascular graft infection * Baseline creatinine greater than or equal to 2.0 mg/dL * History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome) * Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material Anatomical exclusion criteria * Minimum branch vessel diameter less than 5 mm * Thrombus or excessive calcification within the proximal aortic neck * Anatomy that would not allow maintenance of at least one patent hypogastric artery * Anatomy that would not allow primary or assisted patency of the left subclavian artery Expanded Use Arm Inclusion Criteria Patient that meet the criteria for inclusion in the primary study arm but has one or more of the following criteria which would exclude them from the primary study arm: An expanded use arm of the study will broaden inclusion criteria to include patients with the following : * Minimum branch vessel diameter \<5mm * Urgent or emergent presentation * Patient has a contained rupture * Patient has a ruptured aneurysm * Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated * Poor performance status including two major system failures (including but not limited to cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular) * Baseline creatinine greater than or equal to 2.0 mg/dL * Anatomy that does not allow maintenance of at least one hypogastric artery * Anatomy that does not allow primary or assisted patency of the left subclavian artery * Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material * Obstructive stenting of any or all of the visceral vessels * Patient that meets the criteria for inclusion in the primary study arm and: * Would not be eligible for the primary study arm per a documented reason other than those outlined above, and * Per the opinion of the Principal Investigator, with concurrence of the IRB, alternative therapies are unsatisfactory and the probable risk of using the investigational device is no greater than the probable risk from the disease or condition.
Plan de l'étude
Découvrez tous les traitements administrés dans cette étude, leur description détaillée et ce qu'ils impliquent.2 groupes d'intervention sont désignés dans cette étude
Cette étude ne comporte pas de groupe placebo.
Groupes de traitement
Groupe I
ExpérimentalGroupe II
ExpérimentalObjectifs de l'étude
Objectifs principaux
Objectifs secondaires
Centres d'étude
Ce sont les hôpitaux, cliniques ou centres de recherche où l'essai est conduit. Vous pouvez trouver le site le plus proche de vous ainsi que son statut.Cette étude comporte 1 site
Massachusetts General Hospital
Boston, United StatesOuvrir Massachusetts General Hospital dans Google Maps