Suspendido

Visceral Manifold Study for the Repair of Thoracoabdominal Aortic Aneurysms

0 criterios cumplidosConsulta de un vistazo cómo tu perfil cumple con cada criterio de elegibilidad.
Qué se está evaluando

Valiant Thoracoabdominal Stent Graft System

Dispositivo
Quiénes están siendo reclutados

Aneurisma+3

+ Enfermedades Cardiovasculares

+ Aneurisma aórtico toracoabdominal

A partir de 18 años
Ver todos los criterios de elegibilidad
Cómo está diseñado el estudio

Estudio de Tratamiento

Intervencional
Inicio del estudio: octubre de 2020
Ver detalles del protocolo

Resumen

Patrocinador PrincipalMatthew Eagleton
Última actualización: 28 de enero de 2026
Extraido de una base de datos validada por el gobierno.Reclamar como socio

Fecha de inicio: 6 de octubre de 2020

Fecha en la que se inscribió al primer participante.

The primary objective is to assess the use of the thoracic bifurcation and the visceral manifold stent graft system to repair thoracoabdominal aortic aneurysms in patients with appropriate anatomy. The primary intent of the study is to assess safety (i.e. freedom from major adverse events (MAE) at 30 days) and preliminary effectiveness (i.e., treatment success and technical success) of the device (i.e., the proportion of treatment group subjects that achieve and maintain treatment success at one year). Additionally, the study will assess technical success and treatment success at each follow-up interval.

Título OficialVisceral Manifold Study for the Repair of Thoracoabdominal Aortic Aneurysms
NCT04009512
Patrocinador PrincipalMatthew Eagleton
Última actualización: 28 de enero de 2026
Extraido de una base de datos validada por el gobierno.Reclamar como socio

Protocolo

Esta sección proporciona detalles del plan del estudio, incluyendo cómo está diseñado y qué se está evaluando.
Detalles del Diseño

Se reclutarán 15 pacientes

Número total de participantes que el ensayo clínico espera reclutar.

Estudio de Tratamiento

Estos estudios prueban nuevas formas de tratar una enfermedad, condición o problema de salud. El objetivo es determinar si un nuevo medicamento, terapia o enfoque funciona mejor o tiene menos efectos secundarios que las opciones existentes.



Elegibilidad

Los investigadores buscan pacientes que cumplan ciertos criterios, conocidos como criterios de elegibilidad: estado general de salud o tratamientos previos.
Condiciones
Criterios

Cualquier sexo

Sexo biológico de los participantes elegibles para inscribirse.

A partir de 18 años

Rango de edades de los participantes que pueden unirse al estudio.

Voluntarios sanos no permitidos

Indica si personas sanas, sin la condición que se estudia, pueden participar.

Condiciones

Patología

AneurismaEnfermedades CardiovascularesAneurisma aórtico toracoabdominalAneurisma aórticoEnfermedades AórticasEnfermedades Vasculares

Criterios

Inclusion Criteria: Primary Arm Inclusion Criteria: A patient may be entered into the study if the patient has at least one of the following: * An aneurysm with a maximum diameter of \> 5.5 cm or 2 times the normal diameter just proximal to the aneurysm using orthogonal (i.e., perpendicular to the centerline) measurements * Aneurysm with a history of growth \> 0.5 cm in 6 months * Saccular aneurysm deemed at significant risk for rupture * Symptomatic aneurysm greater than or equal to 4.5 cm Other inclusion criteria * Axillary or brachial and iliac or femoral access vessel morphology that is compatible with vascular access techniques, devices or accessories, with or without use of a surgical conduit * Proximal landing zone for the thoracic bifurcation stent graft that has: * ≥ 2.5 cm of nonaneurysmal aortic segment including previously placed graft material (neck) distal to the left subclavian artery (LSA) and a diameter in the range of 26-42 mm * Adequate distance from the celiac artery, in order to accommodate cannulation from the antegrade access point when considering the total deployed length of the thoracic bifurcation and visceral manifold * Iliac artery or aortic distal fixation site, including both native tissue and previously placed graft, greater than or equal to 15 mm in length and diameter in the range of 8 - 25 mm * Age: ≥ 18 years old * Life expectancy: \> 1 year Exclusion Criteria: Primary Arm Exclusion criteria * Patient is a good candidate for and elects for open surgical repair * Can be treated in accordance with the instructions for use with a legally marketed endovascular prosthesis * Is eligible for enrollment in a manufacturer-sponsored IDE at the investigational site * Unwilling to comply with the follow-up schedule * Inability or refusal to give informed consent by patient or legal representative * Urgent or emergent presentation * Patient is pregnant or breastfeeding * Patient has a contained rupture * Patient has a ruptured aneurysm * Patient has a dissection in the portion of the aorta intended to be treated * Obstructive stenting of any or all of the visceral vessels * Poor performance status including two major system failures (including but not limited to cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular) Medical exclusion criteria * Known sensitivities or allergies to the materials of construction of the devices, including nitinol (Nickel: Titanium), polyester, platinum-iridium, polytetrafluoroethylene (PTFE), platinum, gold, polyethylene, or stainless steel. * Known hypersensitivity or contraindication to anticoagulation or contrast media that cannot be adequately medically managed * Uncorrectable coagulopathy * Body habitus that would inhibit x-ray visualization of the aorta or exceeds the safe capacity of the equipment * Patient has had a major surgical or interventional procedure unrelated to the treatment of the aneurysm planned \< 30 days of the endovascular repair * Unstable angina (defined as angina with a progressive increase in symptoms, new onset at rest or nocturnal angina) * Systemic or local infection that may increase the risk of endovascular graft infection * Baseline creatinine greater than or equal to 2.0 mg/dL * History of connective tissue disorders (e.g., Marfan Syndrome, Ehler's Danlos Syndrome) * Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material Anatomical exclusion criteria * Minimum branch vessel diameter less than 5 mm * Thrombus or excessive calcification within the proximal aortic neck * Anatomy that would not allow maintenance of at least one patent hypogastric artery * Anatomy that would not allow primary or assisted patency of the left subclavian artery Expanded Use Arm Inclusion Criteria Patient that meet the criteria for inclusion in the primary study arm but has one or more of the following criteria which would exclude them from the primary study arm: An expanded use arm of the study will broaden inclusion criteria to include patients with the following : * Minimum branch vessel diameter \<5mm * Urgent or emergent presentation * Patient has a contained rupture * Patient has a ruptured aneurysm * Patient has a type B dissection (subacute or chronic) in the portion of the aorta intended to be treated * Poor performance status including two major system failures (including but not limited to cardiovascular, pulmonary, renal, hepatobiliary, and neuromuscular) * Baseline creatinine greater than or equal to 2.0 mg/dL * Anatomy that does not allow maintenance of at least one hypogastric artery * Anatomy that does not allow primary or assisted patency of the left subclavian artery * Prior aneurysm repair that would involve relining of the previously placed graft material requiring placement of the investigational system in a landing zone that expands beyond any limits of the previously placed graft material * Obstructive stenting of any or all of the visceral vessels * Patient that meets the criteria for inclusion in the primary study arm and: * Would not be eligible for the primary study arm per a documented reason other than those outlined above, and * Per the opinion of the Principal Investigator, with concurrence of the IRB, alternative therapies are unsatisfactory and the probable risk of using the investigational device is no greater than the probable risk from the disease or condition.

Plan de Estudio

Conoce todos los tratamientos administrados en este estudio, su descripción detallada y en qué consisten.
Grupos de Tratamiento
Objetivos del Estudio

2 grupos de intervención están designados en este estudio

0% de probabilidad de ser asignado al grupo placebo

Grupos de Tratamiento

Grupo I

Experimental
The Valiant Thoracoabdominal Stent Graft System is comprised of two investigational devices including the Thoracic Bifurcate and the Visceral Manifold. These devices work to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments. The expanded use arm provides broaden inclusion criteria to include select patients excluded from the primary study arm.

Grupo II

Experimental
The Valiant Thoracoabdominal Stent Graft System is comprised of two investigational devices including the Thoracic Bifurcate and the Visceral Manifold. These devices work to facilitate endovascular stenting of the visceral vessels (renals, celiac, SMA) while maintaining flow to the visceral and infrarenal segments.

Objetivos del Estudio

Objetivos Primarios

Objetivos Secundarios

Centros del Estudio

Estos son los hospitales, clínicas o centros de investigación donde se lleva a cabo el estudio. Puedes encontrar la ubicación más cercana a ti y su estado de reclutamiento.

Este estudio tiene una ubicación

Suspendido

Massachusetts General Hospital

Boston, United StatesAbrir Massachusetts General Hospital en Google Maps
Suspendido1 Centros de Estudio