Reliability of Hertel Exophthalmometer Measurements
Colección de datos
Recopilados desde hoy en adelante - ProspectivoExoftalmos
+ Enfermedades Oculares
+ Enfermedades de la Órbita
Cohorte
Seguimiento de la incidencia de una enfermedad para identificar factores de riesgo y comprender su progresión a lo largo del tiempo.Resumen
Fecha de inicio: 1 de mayo de 2012
Fecha en la que se inscribió al primer participante.Aim 1. In order to determine intrauser reliability of the Hertel exophthalmometer, patients will have 2 independent exams using the Hertel exophthalmometer on the same day performed by each of the same researcher (either DAC or HLP) in a blinded fashion. For each patient, we will independently measure the base value and the values for the right and left eye proptosis, respectively, using the same Hertel exophthalmometer. A randomization process will be employed to determine which researcher (either DAC or HLP) will take the first set of measurements. The distance of the observer from the patient will be standardized for all measurements. Patient research data will be de-identified and recorded for each patient and subsequently analyzed for interobserver reliability. Aim 2. In order to determine interuser reliability of the Hertel exophthalmometer, patients will have a second independent exam on the same day by the second observer as determined for Aim 1 above. For each patient, we will independently measure the base value and the values for the right and left eye proptosis, respectively, using the same Hertel exophthalmometer. The distance of the observer from the patient will be standardized for all measurements. Patient research data will be de-identified and recorded for each patient and subsequently analyzed for interobserver reliability. Aim 3. Variability in Hertel measurements may be related in large part to differences in the base measurement. The base measurement is determined by the bony orbital structures and should not be significantly affected over time by the soft tissue remodeling commonly seen in TED and most other orbital disease processes. We will have the second observer re-measure the same patient using the same Hertel exophthalmometer by beginning with the same base measurement determined by the first observer. Again, all measurement distances will be standardized. No other information will be provided to the second observer other than the beginning base measurement. Patient research data will again be de-identified prior to recording the information and subsequently analyzed to determine if beginning with the same base improves interobserver reliability.
Protocolo
Esta sección proporciona detalles del plan del estudio, incluyendo cómo está diseñado y qué se está evaluando.Se reclutarán 85 pacientes
Número total de participantes que el ensayo clínico espera reclutar.Cohorte
Elegibilidad
Los investigadores buscan pacientes que cumplan ciertos criterios, conocidos como criterios de elegibilidad: estado general de salud o tratamientos previos.Cualquier sexo
Sexo biológico de los participantes elegibles para inscribirse.A partir de 18 años
Rango de edades de los participantes que pueden unirse al estudio.Voluntarios sanos permitidos
Indica si personas sanas, sin la condición que se estudia, pueden participar.Condiciones
Patología
Criterios
Plan de Estudio
Conoce todos los tratamientos administrados en este estudio, su descripción detallada y en qué consisten.Objetivos del Estudio
Objetivos Primarios
Objetivos Secundarios
Centros del Estudio
Estos son los hospitales, clínicas o centros de investigación donde se lleva a cabo el estudio. Puedes encontrar la ubicación más cercana a ti y su estado de reclutamiento.Este estudio tiene una ubicación