Measuring Forces Applied During Skull Base Surgery
Dispositif médical Data
+ procedure Data
Données recueillies dès le début de l'étude - ProspectiveMaladies du cerveau+3
+ Maladies du système nerveux central
+ Maladies du système endocrinien
Cas précis
Analyse des caractéristiques de personnes atteintes pour explorer les facteurs (génétiques, environnementaux, etc.) liés à la maladie.Résumé
Date de début de l'étude : 1 octobre 2012
Date à laquelle le premier participant a commencé l'étude.At some time in their lives, 1 in 5 people will have a pituitary tumor, and 1 in 600 of these will have the tumor grow large enough (>1 cm in diameter) that surgical resection is required. Traditionally, surgery to remove pituitary tumors or other tumors at the skull base requires transcranial or transfacial access. In these approaches, large traumatic, often disfiguring, openings must be created in the patient's forehead or cheek. Endonasal skull base surgery reduces invasiveness resulting in less trauma, fewer complications, and shorter surgical time. However, despite the compelling advantages for the patient, only a small percentage of skull base surgeries are done endonasally. While exact statistics are not available, the current best estimate in the literature is that less than 50% and most likely less than 20% of these tumors are addressed by endonasal surgery. The endonasal approach is underemployed despite its demonstrated benefits to the patient because existing surgical instruments have limited dexterity and approach angles, and simultaneously manipulating several of them through a nostril while performing complex surgical procedures is so technically challenging that only a small number of expert surgeons can accomplish it. Even for these experts, mortality rates are non-negligible (0.9%), and there remain contraindications to the endonasal approach, including occlusion of the surgical site by delicate and critical neurovascular structures (e.g. carotid arteries, optic nerves), inability to fully reconstruct the dura due to lack of surgical tool dexterity, and long surgical duration. All of these contraindications are directly related to limitations in instrument dexterity and visualization, which motivates the development of a robotic system for endonasal skull base surgery. Such a robot can potentially increase surgical dexterity and reduce the technical complexity of the procedure for surgeons, thereby increasing the percentage of patient who benefit from the endonasal technique. While many robotic systems have been developed for intravascular interventions as well as natural orifice surgery though other orifices, comparatively few systems have been targeted at endonasal surgery. This is likely due to the smaller size of the nasal cavity and nostril compared to other natural orifices. For endonasal robots, the limited space available in the nostril opening, combined with the need to work dexterously within the cavities in the head, implies that instrument shafts must be small in diameter while enabling dexterous motions of instrument tips. A recently invented robot design that matches these characteristics is the concentric tube robot concept, which is also known as by the name active cannula. A robot suitable for endonasal surgery is being developed (see reference #3), however in order to optimize this robotic system, intraoperative data must be obtained to determine how the robot interacts with the patient's tissues. The aim of this study is to modify a traditional tool used in the operating room to allow determination of forces at the skull base on both hard and soft tissues. This surgical curette will be used in the standard fashion during endonasal skull base surgery, however will provide valuable information. The modified curette will consist of two segments joined by a Nano17 6-axis force sensor. (Image 1) The force sensor is integrated into the shaft of the instrument (a standard neurosurgical ring curette) and insulated from the shaft with two polyetherimide (also known as ULTEM) disks so that no current can be transmitted from the force sensor to the curette. The sensor is held to the shaft by medical grade adhesive and set screws. The patients will be recruited from the PIs clinical practice. Informed consent will be obtained. At the appropriate time during surgery this curette will be used to collect force date. This force transducer operates at 5V (4.8-9V range). These transducers are commonly used in medical and dental research (see reference #5). No additional operating room or anesthesia time will be required.
Protocole
Cette section fournit des détails sur le plan de l'étude, y compris la manière dont l'étude est conçue et ce qu'elle évalue.3 participants à inclure
Nombre total de participants que l'essai clinique vise à recruter.Cas précis
Éligibilité
Les chercheurs recherchent des patients correspondant à une certaine description appelée critères d'éligibilité : état de santé général ou traitements antérieurs du patient.Tout sexe
Le sexe biologique des participants éligibles à s'inscrire.De 18 à 75 ans
Tranche d'âge des participants éligibles à participer.Volontaires sains non autorisés
Indique si les individus en bonne santé et ne présentant pas la condition étudiée peuvent participer.Conditions
Pathologie
Critères
Inclusion criteria: Any male or female patient 18-75 years old undergoing endonasal skull base surgery for a skull base lesion. Competent in decision making process and able to sign a written informed consent form. Exclusion Criteria: -Any patient not able to give written informed consent.
Plan de l'étude
Découvrez tous les traitements administrés dans cette étude, leur description détaillée et ce qu'ils impliquent.Un seul groupe d'intervention est désigné dans cette étude
Cette étude ne comporte pas de groupe placebo.
Groupes de traitement
Objectifs de l'étude
Objectifs principaux
Objectifs secondaires
Centres d'étude
Ce sont les hôpitaux, cliniques ou centres de recherche où l'essai est conduit. Vous pouvez trouver le site le plus proche de vous ainsi que son statut.Cette étude comporte 1 site
Vanderbilt University Skull Base Center
Nashville, United StatesOuvrir Vanderbilt University Skull Base Center dans Google Maps