Study of the Analytical Reproducibility of the Spartan FRX CYP2C19 *2,*3 and *17 Genotyping System.
Datos de Dispositivo
Recopilados desde hoy en adelante - ProspectivoResumen
Fecha de inicio: 1 de agosto de 2012
Fecha en la que se inscribió al primer participante.The FRX system is comprised of hardware and consumable components. The hardware components of the system include an Analyzer (thermal cycler with fluorescence detection capability), a notebook computer and a printer. The consumable component of the FRX system is a sample collection kit. Each kit contains a buccal swab (used to collect the patient sample) and a tube containing the reagents required for genomic DNA extraction and PCR (polymerase chain reaction) amplification stages of the test. The Spartan FRX System is capable of detecting three CYP2C19 SNPs(single nucleotide polymorphism) (*2, *3, *17) in each test performed. An individual sample collection kit is required for each SNP tested; therefore three sample collection kits are required for each test performed on the system. To perform a test, the user collects three buccal samples from the patient and then inserts a sample into each of the three reagent tubes (one for each of the CYP2C19 loci *2, *3 and *17). The reagent tubes are placed into the Analyzer and the FRX system automates the processes of DNA extraction, PCR amplification, fluorescent signal detection and data analysis. The system provides the user with a printed result listing the patient genotypes at the *2, *3 and *17 loci. The objective of the study is to evaluate the performance of the FRX System under multivariate conditions. Specifically, the following variables will be included in the study: Test site - x3 Operator - x6 (2 per site) Day - x15 (5 non-consecutive days per site) FRX System - x16 Test performance is defined as the number of correct genotype calls, expressed as a percentage of the total number of tests performed on the system. For both the first-pass and second-pass results, 1-sided 95% confidence lower limits will be calculated using the score method for the % correct calls (i.e. % agreement). Genotype results from the FRX system will be compared with results of DNA sequencing. The result of the FRX System test will be determined to be correct if the genotype calls for all three SNPs are identical to the genotypes determined by DNA sequencing for that sample/individual. Results of the Reproducibility Study will be acceptable if the lower bound of a 1-sided 95% confidence limit of the total correct call rate per genotype is greater than or equal to 95%, based on second-pass results.
Protocolo
Esta sección proporciona detalles del plan del estudio, incluyendo cómo está diseñado y qué se está evaluando.Se reclutarán 8 pacientes
Número total de participantes que el ensayo clínico espera reclutar.Elegibilidad
Los investigadores buscan pacientes que cumplan ciertos criterios, conocidos como criterios de elegibilidad: estado general de salud o tratamientos previos.Cualquier sexo
Sexo biológico de los participantes elegibles para inscribirse.A partir de 16 años
Rango de edades de los participantes que pueden unirse al estudio.Voluntarios sanos permitidos
Indica si personas sanas, sin la condición que se estudia, pueden participar.Criterios
Plan de Estudio
Conoce todos los tratamientos administrados en este estudio, su descripción detallada y en qué consisten.Objetivos del Estudio
Objetivos Primarios
Centros del Estudio
Estos son los hospitales, clínicas o centros de investigación donde se lleva a cabo el estudio. Puedes encontrar la ubicación más cercana a ti y su estado de reclutamiento.Este estudio tiene 3 ubicaciones
Children's Hospital of Eastern Ontario
Ottawa, CanadaAbrir Children's Hospital of Eastern Ontario en Google MapsOttawa Hospital Research Institute
Ottawa, CanadaMount Sinai Services
Toronto, Canada